Menu
Your Cart

Orthodontic Inter-Proximal Reduction Kit WALDENT Rs.16,964.28 by Dental Trade Mart

Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Out Of Stock
Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Orthodontic Inter-Proximal Reduction Kit WALDENT Dental Instruments Rs.16,964.28
Image is for Illustration Purpose. Read the Description For Complete Details
Orthodontic Inter-Proximal Reduction Kit WALDENT Rs.16,964.28 by Dental Trade Mart
Need Not to Pay Shipping Charges for this Product
Yehhh !! This product qualifies for free shipping


DESCRIPTION:

  • Orthodontic Inter-proximal Stripping Kit is an appropriately designed kit for inter-proximal reduction in orthodontic cases.
  • INTER PROXIMAL REDUCTION (aka Slenderizing, Stripping, Selective Enamel Reduction and Reproximation)
  • Inter proximal reduction (IPR) of enamel involves the removal of outer enamel (0.3–0.5 mm) on the interproximal surfaces of teeth. IPR is one of the techniques that may be used during orthodontic treatment to provide extra intra-arch space in patients with mild to moderate crowding and when extraction therapy is undesirable. 
  • Other advantages of IPR include decreased treatment time and prevention of inter dental gingival retraction.
  • It is also a means to acquire additional space to create ideal tooth alignment.
  • Inter proximal enamel stripping has become an effective orthodontic treatment approach to regain space, improve tooth and gum aesthetics as well as maintain post-treatment stability. Nevertheless, orthodontists should choose appropriate indications by balancing between its benefits and risks.
  • IPR possesses unique advantages in facilitating better treatment outcome in a more conservative and physiological way without harming dental or periodontal tissue.


Inter - proximal Strip Kit :

  • Creates space to improve tooth alignment
  • Helps to improve the bite/occlusion
  • Can increase the stability of the teeth, so they will retain their position long term
  • Can reduce "black triangles" , which is created by the absence of gingival papilla between teeth and gives the appearance of  a dark space or hole.

The procedure can be performed using several methods:

(1) Air rotor stripping with fine tungsten-carbide or diamond burs

(2) The use of diamond-coated stripping disks

(3) The use of hand-held or motor-driven abrasive strips.


INDICATIONS:

  • In cases of Crowding / relapse of crowding
  • In malocclusion cases where extraction is not mandatory
  • To correct black triangles in between the teeth
  • In cases when relapses have taken place, stripping is advisable to allow realignment without labial tipping of anterior teeth into unstable position
  • IPR is used for cosmetic re-contouring, most commonly in reshaping canines to mimic lateral incisors

 

TYPES OF PROXIMAL STRIPS:

90 microns: For use as a saw for opening contacts

60 microns: For reduction

40 microns: For contouring

25 microns: For finishing

15 microns: For Pre-polishing 


FEATURES:

  • Uniquely designed Slow speed Handpiece
  • Different number of Abrasive strips available for different uses
  • Interproximal strip gauge provides appropriate amount of stripping with labelled dimensions


KEY SPECIFICATIONS:

TECHNICAL SPECIFICATIONS:

  • Fits E-Type Handpiece
  • 1.4mm Stroke
  • Autoclavable
  • Optimal Torque
  • Gear ratio: 4:1/1:1


DIRECTIONS TO USE:

  • To begin with, rotated teeth should be aligned prior to reduction if possible to arrange the contact points in a more favorable position. It is optional to separate the teeth 3-4 days before IPR.
  • Coil spring or separators can be used to open space, improving visual and mechanical access and depressing dental papillae to reduce trauma (with separators)
  • This step is often done when the teeth are too rotated and for reduction to be performed prior to alignment.
  • Space opened by coil spring or separator should be measured before reduction to avoid overstripping. Interdental papillae should be protected with thin brass or steel indicator wire.
  • In the process of IPR, an ultra-fine diamond Strip should be placed in the inter-dental space at first followed by reducing mesiodistal widths to the desired dimension.
  • Subsequently, the strip should be inserted below the contact point and swept occlusally.
  • It is suggested that measurement tools be applied to ensure adequate enamel reduction is performed as planned previously. It is also important to ensure that the contact point remains 4.5-5 mm away from the bone crest.
  • However, if it is too close, the size of col will become larger, leading to increased periodontal pocket


WARRANTY:

  • Manufacturer/Importer warranty of 1 Year as applicable for the handpiece only.


PACKAGING:

  • 1 x Contra-angle Handpiece
  • 1 x Chuck/Key
  • 1 x Inter proximal Strip Gauge (0.10mm, 0.15mm, 0.20mm, 0.25mm, 0.30mm, 0.40mm, 0.50mm)
  • Interproximal Strips (15HD, 25HD, 40HD,60HD, 90HD)
Product
Condition Brand New
Warranty / Guarantee 100% Original Guarantee
Shipping Time 2-3 Working Days
Payment Mode Bank Transfer, Credit Card, Debit Card, Net Banking, COD

Write a review

Note: HTML is not translated!
Bad Good
  • Stock: Out Of Stock
  • Model: Orthodontic Inter-Proximal Reduction Kit
Product Sold: 3649
र 19,000
Ex Tax: र 16,964
Price in reward points: 12000